Back to the product
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-085 · Rev. 01 · 13-Oct-2026
Gas detection Brand: Honeywell

Searchline Excel Open Path Infrared Gas Detector

Honeywell Searchline Excel Open Path Infrared Gas Detector

Overview

World-renowned infrared open path flammable gas detector offering unrivalled performance and sensitivity.

Key features

  • Wider area coverage - most likely to pick up any leak
  • Very high speed of response
  • NO unrevealed failure modes - no possibility of blocked gas path to detector
  • Detector location not as critical
  • Indicates size of hazard

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Standards and certification

Supplier: ISO 9001:2015 certified
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 1 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-085 · Rev. 01 · 13-Oct-2026

Searchline Excel Open Path Infrared Gas Detector – technical data

Technical specifications

BrandHoneywell
Alarm SettingsHigh 3 LEL.m / Low 1 LEL.m
Vibration2 to 60 Hz
Weight rangeMedium and Long Range TX: 7 kg and RX: 3.5 kg / Short Range TX: 3.5kg
Path LengthLong Range: 120m to 200m (390ft to 650ft) / Medium Range: 40m to 120m (130 ft to 390 ft) / Short Range: 5m to 40m (15ft to 130ft)
Humidity Range0 to 99% RH (Non-Condensing)
Calibration GasMethane, Ethane, Propane, Butane, Pentane, Ethylene, Propylene, Butadiene
Maximum Pressure105.5 Kpa
Warm Up TimeLess than 1 Hour (Fully Stabilized) / Less than 5 min (Operational)
Speed of ResponseT90 < 3 sec
Signal Output2 mA (1) 0 mA Fault / 2.5 mA (1) Beam Blocked / 21 mA Over Range / 3 mA (1) Dirty Optics / 4 to 20 mA (Max Loop Resistance 600 ohms; Source and Sink Available) and RS485 / 4 to 20 mA Normal Operation (0 to 5 LEL.m)
Misalignment ToleranceLong Range: ± 0.5º (±~170 cm @200m) / Medium Range: ± 0.5° (±~104 cm @120m) / Short Range: ± 0.5° (±~35 cm @40m)
Measuring Range0 to 5 LEL.m
Digital OutputModbus RS485 Multi Drop. (Using DX100(M)) / XNX Universal Transmitter with Modbus Option
Minimum Temperature-40˚C
Ingress ProtectionIP66 / IP67
Power Requirement18 to 32 VDC
Power ConsumptionMedium and Long Range Tx: 10W/13W and Rx: 8W / Short Range Tx: 3.5W/5.0W
Enclosure Material316 Stainless Steel
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 2 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-085 · Rev. 01 · 13-Oct-2026

Searchline Excel Open Path Infrared Gas Detector – technical data, continued

Technical specifications

ApplicationDownstream Chemical Processing Plants / Gas Transport and Pipelines / Large Storage Areas and Buildings / Off-Shore Platforms & Vessels (FPSO’s) / Perimeter Detection
IndustryEnergy / Logistics & Warehouses

Ordering information

BrandHoneywell

Inspection and care

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Storage

Store in a cool, dry place away from direct sunlight, heat and chemicals.

Data given in good faith from manufacturer information and subject to change without notice. Select PPE based on a site risk assessment. Scan the code for the product page.