Back to the product
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-087 · Rev. 01 · 13-Oct-2026
Gas detection EN 50270EN 61000 Brand: Honeywell

Searchline Excel™ Edge Open Path Gas Detector

Honeywell Searchline Excel™ Edge Open Path Gas Detector

Overview

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Key features

  • Fast response to flammable hydrocarbon gas even in low visibility
  • Advanced diagnostics including window clarity and alignment accuracy to enable maximum uptime

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Standards and certification

EN 50270
EN 61000-6
CSA 6101
Supplier: ISO 9001:2015 certified
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 1 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-087 · Rev. 01 · 13-Oct-2026

Searchline Excel™ Edge Open Path Gas Detector – technical data

Technical specifications

BrandHoneywell
Alarm SettingsHigh 3 LEL.m / Low 1 LEL.m / Min 0.5 LEL.m
FeaturesBluetooth® enabled
Wireless TechnologyBluetooth (Range up to 20m) / Bluetooth® (range up to 20 m (66 ft)
Visual IndicatorsBlue: Bluetooth Pairing Mode / Green: Normal / Red: Alarm / Yellow: Fault
Repeatability±0.4 LEL.m
Weight rangeRx: 6.1 kg (13.4 lbs) / Tx: 6.0 kg (13.2 lb)
Path Length60 to 330 m
Dimension4.06 in dia x 12.8 in x 7.09 in
Sensor Range60 m to 330 m (196 to 1,082 ft)
Humidity Range0 to 99% RH (Non-Condensing) / 0–99 % RH Non-condensing
Analog Output Signal Type4-20mA standard
Relay Rated LoadMax. 32 Vdc/ac, max. 2 A resistive load
Relay Output ConfigurationRelay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
Relay Activation SettingsSingle Pole Double Throw (SPDT)
Sensor TypeOpen Path Infrared
Sensing MethodNear Band Infrared
Output Signal Type4 to 20 mA with HART®
Number of Relay Outputs3
MountingUniversal Mounting Bracket Included
Maximum Pressure105.5 kPa (1055 mBar, non-compensated)
Gas TypeFlammable Hydrocarbon
Warm Up TimeLess than 1 Hour (Fully Stabilized) / Less than 5 min (Operational)
Speed of ResponseT90 < 3 sec
Measuring Range0-5 LEL.m
Minimum Temperature-55 °C (-67 °F) / -55°C
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 2 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-087 · Rev. 01 · 13-Oct-2026

Searchline Excel™ Edge Open Path Gas Detector – technical data, continued

Technical specifications

Storage Temperature-55 to +75°C
Analog Output Signal Current4 to 20 mA
Power Requirement24 VDC
Power ConsumptionReceiver: 3.0W (Above +30°C) / Receiver: 4.8W (+30°C to -30°C) / Receiver: 7.4W (Below -30°C) / Transmitter: 11.8W (Below -30°C) / Transmitter: 3.8W (Above +30°C) / Transmitter: 5.6W (+30°C to -30°C)
Battery Run Time10 Years Lifetime
StandardsEN 50270, EN 61000-6, CSA 6101

Ordering information

BrandHoneywell

Inspection and care

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Storage

Store in a cool, dry place away from direct sunlight, heat and chemicals.

Data given in good faith from manufacturer information and subject to change without notice. Select PPE based on a site risk assessment. Scan the code for the product page.