Back to the product
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-098 · Rev. 01 · 13-Oct-2026
Gas detection Brand: Honeywell

Sensepoint XCL Gas Detector

Honeywell Sensepoint XCL Gas Detector

Overview

Once signed in, you may be able to access additional documents for your account.

Key features

  • Gas Detection Sensors & Transmitters

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Standards and certification

Supplier: ISO 9001:2015 certified
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 1 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-098 · Rev. 01 · 13-Oct-2026

Sensepoint XCL Gas Detector – technical data

Technical specifications

BrandHoneywell
Alarm IncludedYes
Display ReadoutLED Indicator
Visual IndicatorsFlashing Blue: Bluetooth Pairing in Progress / Flashing Green and Yellow: Warning / Flashing Red: Alarm / Flashing Yellow: Fault / Green: Normal / Solid Blue: Bluetooth Connection Established / Solid Yellow: Inhibited
Weight range500 g
Dimension113 mm x 113 mm x 59 mm
Humidity Range15 to 90% RH (Non-Condensing)
Analog Outputs0 to 22 mA
Relay Output Configuration2 x @24 V DC/240 V AC, 5A
Wireless CommunicationBluetooth 4.0 (Bluetooth Low Energy)
Maximum Pressure110 kPa
Measuring RangeCO2 (% vol Range): 5.0% vol (Adjustable Between 1.0 and 5.0% vol) / CO2 (ppm Range): 5,000 ppm (Adjustable between 1,000 and 5,000 ppm) / CO: 300 ppm (Adjustable Between 50 and 1000 Ppm) / Combustible: 0 to 100 % LEL (Factory Calibrated to Methane) / H2: 1,000 ppm / H2S High Range: 100 ppm (Adjustable Between 50 and 200 ppm) / H2S Low Range: 50 ppm (Adjustable Between 10 and 50 ppm) / NH3: 200 ppm (Adjustable Between 50 and 200 ppm) / NO2: 20 ppm (Adjustable Between 5 and 50 ppm) / O2: 0 to 25% vol
Digital OutputModbus RTU
Minimum Temperature-20°C
Maximum Operating Current850 mA
Electrical ConnectionPluggable Rising Clamp Style, 0.5 to 1.5 sq.mm (20 to 16 AWG)
Operating Voltage24 VDC
Ingress ProtectionIP65 (Type 4)
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 2 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-098 · Rev. 01 · 13-Oct-2026

Sensepoint XCL Gas Detector – technical data, continued

Technical specifications

Enclosure MaterialPolycarbonate
ApplicationApartments, Accommodation Blocks and Condominiums / Hospitals / Hotel and Leisure / Kitchens and Food Processing / Laboratories / Manufacturing Facilities and Factories / Retail Sites / Transportation and Parking
IndustryCommercial Buildings / Energy / Government & Public Sector / Healthcare / Manufacturing

Ordering information

BrandHoneywell

Inspection and care

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Storage

Store in a cool, dry place away from direct sunlight, heat and chemicals.

Data given in good faith from manufacturer information and subject to change without notice. Select PPE based on a site risk assessment. Scan the code for the product page.