Back to the product
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-110 · Rev. 01 · 13-Oct-2026
Gas detection ATEXIECEX Brand: Honeywell

UltraRAE 3000 + PID9.8 Portable Handheld Computer

Honeywell UltraRAE 3000 + PID9.8 Portable Handheld Computer

Overview

Once signed in, you may be able to access additional documents for your account.

Key features

  • VOC (0-10000ppm)- Benzene (0-200ppm)- Butadiene (0-200ppm)
  • VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Standards and certification

ATEX
IECEX
CSA 10.0005
Supplier: ISO 9001:2015 certified
WEIGHT738 gram
WEIGHT RANGE738 g gram
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 1 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-110 · Rev. 01 · 13-Oct-2026

UltraRAE 3000 + PID9.8 Portable Handheld Computer – technical data

Technical specifications

BrandHoneywell
Weight738 gram
Weight range738 g gram
Instrument Size10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Sensor RangeBenzene 0 -200 ppm / Butadiene 0-200 ppm / VOC (0-10000ppm)- Benzene (0-200ppm)- Butadiene (0-200ppm) / VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
Humidity Range0 to 95% RH (Non-Condensing) percent
Extended Range0.01-10,000 ppm
Minimum Temperature-20 degree Celsius
Maximum Temperature50 degree Celsius
Alarm IncludedYes
Series NameUltraRAE 3000+ PID9.8
LanguagesMulti-Language Support
Alarm TypeAudible (95 dB) / Audible- Visual- Vibrating / Visual (LED)
Alarm SettingsAdditional Diagnostic Alarm and Display Message for Low Battery and Pump Stall / Alarm Latching with Manual Override or Automatic Reset / High: 3 Beeps and Flashes per sec / Low: 2 Beeps and Flashes per sec
Battery Run Time16 Hours hours
Batteries RequiredYes
Batteries IncludedYes
Calibration ProceduresCalibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates / Reflex PID Technology / Two-Point or Three-Point Calibration for Zero and Span
Calibration Points2 / 3
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 2 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-110 · Rev. 01 · 13-Oct-2026

UltraRAE 3000 + PID9.8 Portable Handheld Computer – technical data, continued

Technical specifications

StandardsEurope: ATEX II 2G EEx ia IIC T4 / IECEx CSA 10.0005 Ex ia IIC/IIB GbT4 / US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D / US and Canada: CSA- Classified as Intrinsically Safe for use in Class I- Division 1
Datalogging Interval1 min
Datalogging CapableYes
DataloggingStandard 6 Months at 1 min Intervals
Display Viewing Area28 x 43 mm
Display IncludedYes
Filter IncludedNo
User OptionsAlarms latching with manual override or automatic reset
Sampling Pump Rate400
Sampling Pump Range100 ft meter
Sampling Pump IncludedYes
Sensor TypePhotoionization

Ordering information

BrandHoneywell

Inspection and care

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Storage

Store in a cool, dry place away from direct sunlight, heat and chemicals.

Data given in good faith from manufacturer information and subject to change without notice. Select PPE based on a site risk assessment. Scan the code for the product page.