Back to the product
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-111 · Rev. 01 · 13-Oct-2026
Gas detection ATEXIECEX Brand: Honeywell

UltraRAE 3000 + Portable Handheld Compound Specific VOC Monitor

Honeywell UltraRAE 3000 + Portable Handheld Compound Specific VOC Monitor

Overview

The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

Key features

  • Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
  • High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
  • Lower risk of false alarms through advanced speciation method
  • Total VOC measurement mode with extended range of 0.05 to 10,000 ppm

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Standards and certification

ATEX
IECEX
CSA 10.0005
Supplier: ISO 9001:2015 certified
WEIGHT26 ounce av / 738 gram
WEIGHT RANGE738 g gram
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 1 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-111 · Rev. 01 · 13-Oct-2026

UltraRAE 3000 + Portable Handheld Compound Specific VOC Monitor – technical data

Technical specifications

BrandHoneywell
Weight26 ounce av / 738 gram
Instrument Size10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Weight range738 g gram
Humidity Range0 to 95% RH (Non-Condensing) percent / 0%-95% percent
Extended Range0.01-10,000 ppm
Sensor RangeBenzene 0 -200 ppm / Butadiene 0-200 ppm / VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
Minimum Temperature-20 degree Celsius / -4 degree Fahrenheit
Maximum Temperature122 degree Fahrenheit / 50 degree Celsius
Alarm SettingsAdditional Diagnostic Alarm and Display Message for Low Battery and Pump Stall / Alarm Latching with Manual Override or Automatic Reset / High: 3 Beeps and Flashes per sec / Low: 2 Beeps and Flashes per sec
Alarm TypeAudible (95 dB) / Visual (LED)
Alarm IncludedYes
Series NameUltraRAE 3000+
LanguagesMulti-Language Support
Batteries RequiredYes
Batteries IncludedYes
Battery Run Time16 hours
Calibration ProceduresCalibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates / Reflex PID Technology / Two-Point or Three-Point Calibration for Zero and Span
Calibration Points2 / 3
StandardsEurope: ATEX II 2G EEx ia IIC T4 / IECEx CSA 10.0005 Ex ia IIC/IIB GbT4 / US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D
Datalogging Interval1 min
Datalogging CapableYes
SureSafe Safety & Lifting Solutions Pvt. Ltd. · Bengaluru · Mumbai · +91 88804 80495 · sales@suresafesafety.com · suresafesafety.com 2 / 3
SureSafe Safety & Lifting Solutions Pvt Ltd
PRODUCT DATASHEETDoc. SSLS/DS/GD-111 · Rev. 01 · 13-Oct-2026

UltraRAE 3000 + Portable Handheld Compound Specific VOC Monitor – technical data, continued

Technical specifications

DataloggingStandard 6 Months at 1 min Intervals / Standard 6 months at one-minute intervals
Display Viewing Area28 x 43 mm
Display IncludedYes
Filter IncludedNo
User OptionsAlarms latching with manual override or automatic reset
Sampling Pump IncludedYes
Sampling Pump Range100 ft meter / 100ft (30m) meter
Sampling Pump Rate400
Number of Sensors Included3

Ordering information

BrandHoneywell

Inspection and care

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Storage

Store in a cool, dry place away from direct sunlight, heat and chemicals.

Data given in good faith from manufacturer information and subject to change without notice. Select PPE based on a site risk assessment. Scan the code for the product page.