ISO 9001:2015 certified · Manufacturer, importer and dealer

UltraRAE 3000 + Portable Handheld Compound Specific VOC Monitor

The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market.

ATEXIECEX
DatasheetSpecifications, standards, care
  • Test certificate available on request

Specifications

BrandHoneywell
Weight26 ounce av / 738 gram
Instrument Size10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Weight range738 g gram
Humidity Range0 to 95% RH (Non-Condensing) percent / 0%-95% percent
Extended Range0.01-10,000 ppm
Sensor RangeBenzene 0 -200 ppm / Butadiene 0-200 ppm / VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
Minimum Temperature-20 degree Celsius / -4 degree Fahrenheit
Maximum Temperature122 degree Fahrenheit / 50 degree Celsius
Alarm SettingsAdditional Diagnostic Alarm and Display Message for Low Battery and Pump Stall / Alarm Latching with Manual Override or Automatic Reset / High: 3 Beeps and Flashes per sec / Low: 2 Beeps and Flashes per sec
Alarm TypeAudible (95 dB) / Visual (LED)
Alarm IncludedYes
Series NameUltraRAE 3000+
LanguagesMulti-Language Support
Batteries RequiredYes
Batteries IncludedYes
Battery Run Time16 hours
Calibration ProceduresCalibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates / Reflex PID Technology / Two-Point or Three-Point Calibration for Zero and Span
Calibration Points2 / 3
StandardsEurope: ATEX II 2G EEx ia IIC T4 / IECEx CSA 10.0005 Ex ia IIC/IIB GbT4 / US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D
Datalogging Interval1 min
Datalogging CapableYes
DataloggingStandard 6 Months at 1 min Intervals / Standard 6 months at one-minute intervals
Display Viewing Area28 x 43 mm
Display IncludedYes
Filter IncludedNo
User OptionsAlarms latching with manual override or automatic reset
Sampling Pump IncludedYes
Sampling Pump Range100 ft meter / 100ft (30m) meter
Sampling Pump Rate400
Number of Sensors Included3

Key features

  • Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
  • High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
  • Lower risk of false alarms through advanced speciation method
  • Total VOC measurement mode with extended range of 0.05 to 10,000 ppm

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Care and replacement

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Related products

Bulk enquiry

Share quantity, sizes.

+91 88804 80495
Monday to Saturday
Bengaluru · Mumbai