BW™ Flex
Once signed in, you may be able to access additional documents for your account.
ATEXIECEX
DatasheetSpecifications, standards, care
- Test certificate available on request
Specifications
| Brand | Honeywell |
|---|---|
| Weight | 189 gram |
| Weight range | With Catalytic LEL: 189 g (6.7 oz) with Alligator Clip and 173 g (6.1 oz) with Klick Fast Stud gram / With IR LEL: 186 g (6.6 oz) with Alligator Clip and 170 g (6.0 oz) with Klick Fast Stud gram |
| Instrument Size | 108.2mm x 61.5mm x 43.2mm (4.29in x 2.44in x 1.7in) with Alligator Clip |
| Sensor Range | CL2: 20 ppm / CO-H: 1000 ppm / CO: 1000 ppm / COSH Dual Toxic CO: 1,000 ppm / COSH Dual Toxic H2S: 100 ppm / H2S: 200 ppm / HCN: 50 ppm / LEL-CB-F: 100% LEL / LEL-CB-UF: 100% LEL / LEL-IR: 100% LEL / NDIR-CO2: 5% VOL (50000 ppm) / NO2: 20 ppm / NO: 100 ppm / O2: 25% VOL / SO2: 20 ppm |
| Humidity Range | 0%-95% RH percent / 5 to 95% RH (Non-Condensing) percent |
| Minimum Temperature | -40 degree Celsius |
| Maximum Temperature | 60 degree Celsius |
| Alarm Included | Yes |
| Series Name | Honeywell BW Flex 4/5 Series |
| Alarm Type | Audible (95 dB) / Vibrating / Visual |
| Alarm Settings | Low, High, TWA, STEL, Negative Drift, OL (Over Limit), Multi-Alarm, Low Battery |
| Battery Run Time | 40 Days @8 Hours of Use/Day with NDIR CH4 Sensor hours / Up to 15 Hours with Catalytic LEL hours |
| Batteries Required | Yes |
| Batteries Included | Yes |
| Standards | ATEX, IEC Ex, CSA, FTZU, INMETRO, GOSST, CCCF, CPA, KRS, MED, DNV, SABS, FCCID, IC, UKCA, CE |
| Certifications - Hazloc | ATEX, IECEX |
| Datalogging | 45 days of data at 15 sec interval, 8hrs/day |
| Filter Type | Catalytic Bead Filtered |
| Filter Required | Yes |
| Filter Included | Yes |
| User Options | Always ON / Apply Enforcement Policies / Assign Worker and Location Assignments / Change High, Low, TWA and STEL Alarm Set Points / Latching Alarms / Peak Hold Function / Set Calibration and/or Bump Test Reminders |
| Sensor Type | Catalytic, IR |
| Number of Sensors Included | 4 |
| Warranty | 3 Years |
| Wireless Technology | BLE |
| Ingress Protection | IP66/68 / IP66/IP68 |
| Gas Type | H2S, CO, O2, LEL, SO2 |
| External Calibration | IntelliDox Instrument Management System |
| Decibels | 95 decibel |
| Combustible Concentration | LEL-CB-F 100% LEL / LEL-CB-UF 100% LEL / LEL-IR 100% LEL |
Key features
- With Catalytic LEL: 189 g (6.7 oz) with Alligator Clip and 173 g (6.1 oz) with Klick Fast Stud gram
- With IR LEL: 186 g (6.6 oz) with Alligator Clip and 170 g (6.0 oz) with Klick Fast Stud gram
Applications
- Confined space entry
- Oil, gas and petrochemical
- Wastewater and sewage
- Steel and chemical plants
Care and replacement
Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.
Related products
Bulk enquiry
Share quantity, sizes.
Enquiry received.