ISO 9001:2015 certified · Manufacturer, importer and dealer

MultiRAE Lite Pumped ATX PID LEL Portable Multi Gas Monitor

Once signed in, you may be able to access additional documents for your account.

ATEXIECEX
DatasheetSpecifications, standards, care
  • Test certificate available on request

Specifications

BrandHoneywell
Weight880 gram
Weight range880 g gram
Instrument Size7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Sensor RangeNH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
Humidity Range0 to 95% RH (Non-Condensing) percent / 0%-95% percent
Minimum Temperature-20 degree Celsius
Maximum Temperature50 degree Celsius
Alarm IncludedYes
Series NameMultiRAE Lite Pumped ATX PMP PID LEL
LanguagesArabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
Alarm TypeAudible (95 dB @30 cm) / Vibrating / Visual (Flashing Bright Red LEDs)
Charging Time6 hours / 9 hours
Battery Run TimeAlkaline Adapter with 4 X AA Batteries 6 Hours hours / Extended Duration Li-Ion (18 Hours) hours / Rechargeable Li-Ion (12 Hours) hours
Batteries RequiredYes
Batteries IncludedYes
Calibration ProceduresAutomatic with AutoRAE 2 Test and Calibration System or Manual
CalibrationAutomatic with AutoRAE 2 Test and Calibration System or Manual
StandardsATEX: 0575 II 1G Ex ia IIC T4 Ga / ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed / ATEX: I M1 Ex ia I Ma / CSA: Class I, Div 1, Group A, B, C, D, T4 / CSA: Class II, Div 1, Group E, F, G T85°C / IECEx/ANZEx: Ex ia I Ma / IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: Ex ia IIC T4 Ga / IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: I M1 Ex ia I Ma
Certifications - PerformanceISA-12.13.01 / LEL CSA C22.2 No. 152
Datalogging Interval1 min
Datalogging CapableYes
DataloggingContinuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7) / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
Display TypeMonochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
Display ReadoutMan Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality / Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor / STEL, TWA, Peak and Minimum Values
Display Matrix128 x 160
Display IncludedYes
User Options3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
Sampling Pump Range100ft (30m) meter
Sampling Pump IncludedYes
Sensor TypePID Combustible LEL

Key features

  • Audible (95 dB @30 cm)
  • Visual (Flashing Bright Red LEDs)

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Care and replacement

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.

Related products

Bulk enquiry

Share quantity, sizes.

+91 88804 80495
Monday to Saturday