Specifications
| Brand | Honeywell |
|---|---|
| Weight | 880 gram |
| Weight range | 880 g gram |
| Instrument Size | 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm] |
| Sensor Range | NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm) |
| Humidity Range | 0 to 95% RH (Non-Condensing) percent / 0%-95% percent |
| Minimum Temperature | -20 degree Celsius |
| Maximum Temperature | 50 degree Celsius |
| Alarm Included | Yes |
| Series Name | MultiRAE Lite Pumped ATX PMP PID LEL |
| Languages | Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish |
| Alarm Type | Audible (95 dB @30 cm) / Vibrating / Visual (Flashing Bright Red LEDs) |
| Charging Time | 6 hours / 9 hours |
| Battery Run Time | Alkaline Adapter with 4 X AA Batteries 6 Hours hours / Extended Duration Li-Ion (18 Hours) hours / Rechargeable Li-Ion (12 Hours) hours |
| Batteries Required | Yes |
| Batteries Included | Yes |
| Calibration Procedures | Automatic with AutoRAE 2 Test and Calibration System or Manual |
| Calibration | Automatic with AutoRAE 2 Test and Calibration System or Manual |
| Standards | ATEX: 0575 II 1G Ex ia IIC T4 Ga / ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed / ATEX: I M1 Ex ia I Ma / CSA: Class I, Div 1, Group A, B, C, D, T4 / CSA: Class II, Div 1, Group E, F, G T85°C / IECEx/ANZEx: Ex ia I Ma / IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: Ex ia IIC T4 Ga / IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: I M1 Ex ia I Ma |
| Certifications - Performance | ISA-12.13.01 / LEL CSA C22.2 No. 152 |
| Datalogging Interval | 1 min |
| Datalogging Capable | Yes |
| Datalogging | Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7) / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs) |
| Display Type | Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature |
| Display Readout | Man Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality / Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor / STEL, TWA, Peak and Minimum Values |
| Display Matrix | 128 x 160 |
| Display Included | Yes |
| User Options | 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs) |
| Sampling Pump Range | 100ft (30m) meter |
| Sampling Pump Included | Yes |
| Sensor Type | PID Combustible LEL |
Key features
- Audible (95 dB @30 cm)
- Visual (Flashing Bright Red LEDs)
Applications
- Confined space entry
- Oil, gas and petrochemical
- Wastewater and sewage
- Steel and chemical plants
Care and replacement
Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.