ISO 9001:2015 certified · Manufacturer, importer and dealer

MultiRAE Lite Pumped Multi Gas Detector

Once signed in, you may be able to access additional documents for your account.

ATEXIECEX
DatasheetSpecifications, standards, care
  • Test certificate available on request

Specifications

BrandHoneywell
Weight31 ounce av / 880 gram
Instrument Size7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
Weight range880 g gram
Humidity Range0 to 95% RH (Non-Condensing) percent / 0%-95% percent
Sensor RangeCarbon Dioxide (CO2) NDIR 0 to 50,000 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol / NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
Minimum Temperature-20 degree Celsius / -4 degree Fahrenheit
Maximum Temperature122 degree Fahrenheit / 50 degree Celsius
Alarm IncludedYes
Series NameMultiRAE Lite Pumped
LanguagesArabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
Alarm TypeAudible (95 dB @30 cm) / Vibrating / Visual (Flashing Bright Red LEDs)
Batteries RequiredYes
Batteries IncludedYes
Battery Run Time12-18 hours / Alkaline Adapter with 4 X AA Batteries 6 hours / Extended Duration Li-Ion 18 hours / Rechargeable Li-Ion 12 hours
Charging Time6 hours / 9 hours
Calibration ProceduresAutomatic with AutoRAE 2 Test and Calibration System or Manual
CalibrationAutomatic with AutoRAE 2 Test and Calibration System or Manual
Certifications - PerformanceISA-12.13.01 / LEL CSA C22.2 No. 152
StandardsATEX: 0575 II 1G Ex ia IIC T4 Ga / ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed / ATEX: I M1 Ex ia I Ma / CSA: Class I, Div 1, Group A, B, C, D, T4 / CSA: Class II, Div 1, Group E, F, G T85°C / IECEx/ANZEx: Ex ia I Ma / IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: Ex ia IIC T4 Ga / IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed / IECEx: I M1 Ex ia I Ma
Datalogging Interval1 min
Datalogging CapableYes
DataloggingContinuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7) / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
Display IncludedYes
Display ReadoutMan Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality / Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor / STEL, TWA, Peak and Minimum Values
Display Matrix128 x 160
Display TypeMonochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
User Options3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected / User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
Sampling Pump IncludedYes
Sampling Pump Range100ft (30m) meter
Number of Sensors Included25

Key features

  • Multi-gas monitor for 1-6 gases
  • Pumped and diffusion models available
  • More than 25 different chemical sensors
  • Fully automatic bump testing and calibration
  • Real-time access to readings at central command
  • Swap out sensors as needed
  • Simple maintenance with replaceable sensors, pump, and battery
  • 5-way local and remote wireless alarm
  • Multi-language capability – up to 18 languages
  • Device Management with Honeywell Sotera™ Express

Applications

  • Confined space entry
  • Oil, gas and petrochemical
  • Wastewater and sewage
  • Steel and chemical plants

Care and replacement

Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.