BW™ Solo Lite Single Gas Detector
Once signed in, you may be able to access additional documents for your account.
DatasheetSpecifications, standards, care- Test certificate available on request
Specifications
| Brand | Honeywell |
|---|---|
| Warranty | 1 Year for NH3, Cl2, O3, ETO, ClO2, HCI, HF Sensors / 2 Years for 4-Series Detectors and Sensors / 3 Years for 1-Series Detectors and Sensors (H2S, CO, O2, CO2) / 3 years for 1-Series sensors and 1-Series detectors (excluding battery) |
| Maximum Temperature | 60 degree Celsius |
| Weight | 103 gram |
| Alarm Settings | Low, High, TWA, STEL, Non-Compliance |
| Alarm Included | Yes |
| Alarm Type | Audible (95 dB) / Audible, Visual, Vibrating / Vibrating / Visual |
| Datalogging Sessions | 5 Events |
| Datalogging Interval | 5 sec |
| Datalogging | Six months at 5 second intervals |
| Display Included | Yes |
| Display Readout | Real-Time Reading of Gas Concentrations in ppm or mg/m3; Battery Status; Wireless ON/OFF |
| Display Type | FSTN Dot Matrix LCD Display |
| User Options | Assign Worker and Location Assignments / Change High, Low, TWA and STEL Alarm Setpoints / Enable IntelliFlash and Non-Compliance Indicators / Language Select: English, Russian, Japanese, Chinese, Korean / Latching Alarms / Reset TWA, STEL and Peak Readings / Reset TWA- STEL and / Set Calibration and/or Bump Test Reminders |
| Wireless Technology | BLE |
| Instrument Size | 2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm |
| Weight range | 103 to 116 g |
| Dimension | H: 7.0 cm W: 6.7 cm D: 4.1 cm |
| Humidity Range | 0 to 95% RH (Non-Condensing) |
| Sensor Range | H2S (0-200ppm), CO (0-2000ppm), O2 (0-30%vol), Cl2 (0-50ppm), ClO2 (0-1ppm), ETO (0-100ppm), H2 (0-1000ppm), HCN (0-100ppm), NH3 (0-1000ppm), NO (0-250ppm), NO2 (0-100ppm), O3 (0-1ppm), PH3 (0-5ppm), SO2 (0-100ppm) |
| Calibration | Automatic with IntelliDoX, or Manual |
| Display Viewing Area | 128 x 64 with Backlighting |
| Sensor Type | Electrochemical Sensors (4-Series) |
| Gas Type | H2S, CO, O2, Cl2, ClO2, ETO, H2, HCN, NH3, NO, NO2, O3, PH3, SO2 |
| Communication and Data Download | BLE (Wireless Model Only) or on Cell Phone via BLE (Wireless Model Only) / Data Download and Instrument Setup and Upgrades on PC via IntelliDoX / Wireless Data and Status Transmission via Built-in BLE (Wireless Model Only) |
| Dust and Water Resistance | IP68 (1.2 m for 45 min) |
| Wireless Frequency | Bluetooth 2402~2480 MHz |
| Wireless Approvals | FCC ID: SU3BWS1 / IC: 20969-BWS1 / RE-D Directive 2014/53/EU |
| Wireless Network | BLE (Bluetooth Low Energy) |
| Sampling | Difussion |
| Batteries Required | ER14335 2/3AA Lithium Thionyl Chloride Battery |
Key features
- Accessing the Menu and Info Screen
- Replace Battery and Battery Door
- Replace Sensor Filter
- Safety Suite Device Configurator
- Safety Suite Device Manager
- Sensor Replacement - 1 Series
- Sensor Replacement - 4 Series
Applications
- Confined space entry
- Oil, gas and petrochemical
- Wastewater and sewage
- Steel and chemical plants
Care and replacement
Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.