MiniRAE Lite + Portable Handheld VOC Monitor
This affordable hand-held monitor for VOCs provides superior reliability for leak detection and environmental cleanup and remediation.
ATEX
DatasheetSpecifications, standards, care
- Test certificate available on request
Specifications
| Brand | Honeywell |
|---|---|
| Weight | 26 ounce av / 738 gram |
| Instrument Size | 10 in L x 3.0 in W x 2.5 in H (25.5 x 7.6 x 6.4 cm) |
| Weight range | 738 g gram |
| Humidity Range | 0 to 95% RH (Non-Condensing) percent / 0%-95% percent |
| Sensor Range | VOCS: 0-999.9 ppm / VOCS: 1,000-5,000 ppm |
| Minimum Temperature | -20 degree Celsius / -4 degree Fahrenheit |
| Maximum Temperature | 113 degree Fahrenheit / 50 degree Celsius |
| Alarm Settings | Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall / Alarm Latching with Manual Override or Automatic Reset / High: 3 Beeps and Flashes per sec / Low: 2 Beeps and Flashes per sec |
| Alarm Type | Audible (95 dB) / Visual (Flashing Bright Red LEDs) |
| Alarm Included | Yes |
| Series Name | MiniRAE Lite + |
| Languages | Multi-Language Support with 12 Languages Encoded |
| Batteries Required | Yes |
| Batteries Included | Yes |
| Battery Run Time | 12 hours |
| Calibration Points | 2 |
| Calibration | Two-Point Calibration for Zero and Span. Patented AutoZero Feature |
| Standards | ATEX II 2G EEx ia IIC T4 |
| Datalogging Interval | 1 min |
| Datalogging Capable | Yes |
| Datalogging | Standard 6 Months at 1 min Intervals / Standard 6 months at one-minute intervals |
| Display Viewing Area | 28 x 43 mm |
| Display Included | Yes |
| Display Readout | Date and Time / High and low values / VOCS as ppm by volume |
| Display Type | LED Backlight |
| Filter Required | External |
| Filter Included | No |
| Filter Type | 5 Porous Metal Filters with O-Rings |
| User Options | Alarms latching with manual override or automatic reset |
| Sampling Pump Location | Horizontally and Vertically |
Key features
- Portable handheld VOC monitor
- PID measures from 0-5,000 ppm
- 3-second response time
- Humidity compensation
- Rugged housing for harsh environments
- Multi-language capability – up to 10 languages
- Logs up to 6 months of data at 1-minute intervals
Applications
- Confined space entry
- Oil, gas and petrochemical
- Wastewater and sewage
- Steel and chemical plants
Care and replacement
Keep sensors and filters clean, charge batteries as directed and record bump tests and calibrations.
Related products
Bulk enquiry
Share quantity, sizes.
Enquiry received.
We will call or WhatsApp you shortly. Anything to add? Call +91 88804 80495.